Pentair easy touch not communicating with pump

Written by Alcyqoi NisrpsqpLast edited on 2024-07-06
Page 1 ® IntelliFlo VS+ SVRS Variable Speed Programmable Pump with Safety Vacuum Release System (SVRS) .

To connect your pentair screenlogic app, follow these simple steps: 1. Download and install the pentair screenlogic app from your device’s app store. 2. Ensure your pentair pool or spa system is connected to your home’s wi-fi network. 3. Open the screenlogic app and tap on “connect” or “enter ip address” if prompted.*PVC valves are not recommended for extreme temperature applications. 263026 263042 263045 521109 520856 263057 263077 Note: All Pentair® 2- and 3-way valves are positive seal. All SolarTouch controller models include one 3HP Solar Booster Pump SPST relay and one 3HP Pressure Cleaner Booster Pump delay SPST relay.Up/Down button: Set speed of the pump from 15 to 130 GPM. The default flow rate is 30 GPM. The preset speed for each button is: Speed 1 button 1100 RPM (30 GPM), Speed 2 button 1500 RPM, Speed 3 button 2350 RPM, and Speed 4 button 3110 RPM. Right button (GPM/PSI): Move to PSI (pounds per square inch) pressure setting.Do not plug in the AC adapter to a power source within five (5) feet of the pool and spa. Canadian installations require a minimum of (3) meters from pool water. Do not recharge outdoors. Only use Pentair approved AC adapter transformer. The MobileTouch wireless controller is water resistant and can be exposed to temporary splashing or wet hands.Remote Operation The heat pump may be connected to an automation system via the remote spade terminals on the back of the control board or via the RS-485 communication connector on the back of the control board. ® ® NOTE: Remote connection via the RS-485 connector is only available on IntelliTouch and EasyTouch software version 1.11 or higher.This is a Pentair Wireless Remote with 4-Auxiliary for EasyTouch Pool and Spa Automatic Control Systems. ... including pumps, filters, signs, and maintenance supplies at highly competitive prices. With over decades of experience, Poolweb.com has built a solid reputation among pool owners and commercial facilities for providing exceptional ...According to Union Community College Anatomy and Physiology class materials, the trabeculae carneae aids the ventricles of the heart in pumping blood.Fully automated Pentair system. 3 pumps for edge, floor cleaner, and main pump. All systems work per schedule but main pump won't kick on by schedule but does turn off per schedule. Have t …3,024.54. $. 2,874.54. EasyTouch PL4 and PSL4 control systems provide economical yet sophisticated control over filtration pumps lighting chemical management and more. The EasyTouch PL4 system is designed for a single body of water while the EasyTouch PSL4 system is designed to control a pool and spa combination.New pool owner: I have a Pentair Easytouch control 4 with a Pentair intelliflo VSF pump. ... the pump would not start in the morning, ... Easy Touch and Intelliflo pump not communicating. Merrtpa; Jul 20, 2023; Everything Else; Replies 4 Views 184.I day Fully toward a loss- and feelings like I have tried entirety. Hoping someone here can promote. I have an Intelliflo VF, Easytouch 8, and ScreenLogic2. When in Auto mode my pump possesses "display non active" so the easytouch and cross-examine been communicating. I currently have one schedule to the pool only...Jan 18, 2022 · Look in your EasyTouch menus to see how many pumps your EasyTouch supports [Settings -> IntelliFlo]. If there are slots for 2 pumps on your EasyTouch then you are golden. The limitations will be with EasyTouch not the 4x160 pump since that pump can be addressed 1-4 and likewise communicate with IntelliTouch where the protocols are identical.The Pentair Superflo VS is being re-released with some new automation functionality. We previously recommended against this pump for a couple of reasons, primarily due to the analog automation options and 1.5 HP rating. The new automation options make it a good choice under certain circumstances. We have always recommended "oversizing ...Place the spring half of the shaft seal onto the motor shaft. Using a 1/4" hex-key wrench, hold the motor shaft in place at the rear of the motor. This prevents the motor shaft from spinning while reinstalling the impeller and impeller screw. Reinstall the impeller onto the motor shaft clockwise.ScreenLogic2 Interface allows you to control the key functions EasyTouch control systems, using controllers such your Android® and iOS® device, Web browsers on Mac® and PC computers. The ScreenLogic Bundle conveniently includes the Protocol Adapter (520500 and the ScreenLogic Interface Wireless Connection Kit (523434).Push-button controls and intuitive displays take the guesswork and frustration out of setting up and modifying control programs. The EasyTouch PL4 control system is a four-circuit system designed for a single body of water, while the EasyTouch PSL4 system is a four-circuit system designed to control a pool/spa combination.Open the app and select “add system” or “connect to system”. 5. Follow the on-screen prompts to input your system’s unique network name and password. 6. Once the information is entered correctly, the app will connect …Open the heater control box, you will see a terminal marked "FS" fireman switch. Take out the jumper, and connect a wire to each. Then at the Easytouch open the top section, and connect the same two wires to "gas heater". Does not matter which wire goes to which. Use a 16 guage wire or better.communication cable and power source (9-24V DC) from the automation control system circuit board. Note: The IntelliComm II Interface adapter will always use ADDRESS 1 to communicate with the IntelliFlo pump. Note: The IntelliComm II Interface adapter can be used with IntelliTouch®, EasyTouch® and SunTouch® systems, when additional pumps are ...I finally replaced my old 1-speed pump and got the Pentair SuperFlo VS. The pump’s power is wired into my EasyTouch panel but I don’t have a communication cable yet. I have the pump to run 24/7 so I really don’t need a schedule/timer set on my EasyTouch.. I deleted what was originally set for the pump. I turn the pump on using the FILTER ...Mounting the Load Center and Power Center. Mount the Load Center (EasyTouch® Control System enclosure show below) and Power Center on a flat vertical surface, such as a wall or post at eye level, at least 5 ft. (1.5 m), (Canada 3 m (9.75 ft)) from the pool, spa or hot tub. To mount the Load Center and Power Center:A quiet and efficient air handler for almost any installation. Reduce energy costs with the high-efficiency, next-generation blower and "A" coil design of the YORK® JHC Variable Speed Air Handler. Its advanced, variable speed ECM blower uses up to 80% less electricity than traditional technologies. Designed for use with the NEW, Low-GWP R ...Grab a paper clip and press the reset button three times in the hole of the protocol adapter before waiting 30 seconds for it to work again. Try uninstalling and then reinstalling the app once too. A Different Subnet. A different subnet can block out both connections. In this case, you may not see any of the Screenlogic protocol adapters when ...Install the pump as close to the pool or spa as possible. To reduce friction loss and improve eficiency, use short, direct suction and return piping. Install a minimum of 5 ft. (1.5 m) from the inside wall of the pool and spa. Canadian installations require a minimum of 9.8 ft. (3 m) from the inside wall of the pool.8. Compact Design. With dimensions of 26 inches in height, 17 inches in width, and 5.25 inches in depth, the EasyTouch Control System features a compact design that can be easily installed near the pool or spa equipment, saving space and minimizing wiring and installation costs. 9. Certifications.ScreenLogic2 Interface allows you to control the key functions EasyTouch control systems, using controllers such your Android® and iOS® device, Web browsers on Mac® and PC computers. The ScreenLogic Bundle conveniently includes the Protocol Adapter (520500 and the ScreenLogic Interface Wireless Connection Kit (523434).If the display does not tell you to consult the easytouch, there is a communication issue between the pump and controller (which means something is …From https://www.justanswer.com/ythiJustAnswer Customer: I have a pentair easy touch that is reading "no comm" after power went out to house during storm.Jus...FLOW CONTROL. Our variable speed and flow pool pumps adjust to meet your pool's changing needs. *Savings based on variable speed pump compared to a single-speed pump running 12 hours per day at an average of $0.16 per kWH in a 20,000-gallon pool. Actual savings may vary based on local utility rates, pool size, pump run time, pump horsepower ...Easytouch will be cheaper but was discontinued back in April. So it will not be getting forward support or updates, and it does not communicate with newer pumps like the IF3. Intellicenter is the current version and what I'd recommend as it'll have lots of updates and support going forwards.I'm having trouble heating my spa. I have all Pentair equipment, Easy Touch controller with wireless remote, intelliflo pump and Mastertemp 400 natural gas heater.When I turn the spa on, it starts normally and the heater will come on and then everything runs for a few mintutes, maybe 10 or 15 and then the pump will just stop the heater then goes into high temp mode since the water has suddenly ...As low as $80.63/mo*. The Pentair EC-520540 Easytouch Control. All functions are controlled with easy, one-button access from the self-contained load center. Includes 125 Amp breaker base. Optional controllers included.IntelliProXF VSF pump is the first variable speed and flow pump that adjusts to changes in flow system conditions to maintain its programmed flow rate. With its available performance and efficiency, it is perfectly suited for large and feature rich pools with high flow demand. Eight programmable speed or flow settings and built-in timer.Jan 28, 2022 · Jan 28, 2022. #1. New pool is in startup. Pool schedule has pump going on at 9:30 AM, but time may have been off a minute or two. Pump didn't start at 9:30. Pool startup guy arrived at house around 9:31, pump wasn't on and he hit Speed button 1 which is Manual 2000 RPM on Pentair VSF and it turned on. He did his work with testing, vacuuming ...I have set up me ISY to send comments to my Pentair Light Touch pool control system. The Pentair systems how RS485 to communicate with their wired rule panels. You can get low (<$10) RS232-RS485 protocol converters (search "Hexin") and apply ampere standard serial-ethernet jumper, or use adenine bridge...We have 2 Pentair EasyTouch 4 manuals available for free PDF download: User Manual, Installation Manual.Pentair Easy Touch Wifi Upgrade. The Pentair Easy Touch Wifi Upgrade allows pool owners to control their filtration system, pumps and pool lighting from anywhere via a smartphone or tablet. With this upgrade, you can easily monitor and adjust water temperature, filter cycles and other settings all with the touch of your finger.It's part two of the Vanderpump Rules reunion. Lala is still trying to understand things that have nothing to do with her, and Katie is just mad… pretty much the whole time. First, it was Lala coming at her, then the Scheana/Schwartz makeout gets brought up, and finally, Jo comes out to try and speak her truth. That doesn't go so well, as Schwartz tries to gaslight Jo into thinking they ...Hi, I'm having trouble with own EasyTouch verfahren and pool pump, (pentair superflo VS). That pump is not turning in the at this designated clock, and I have till handheld turn an pool pump on using who panel on the pump itself. Also, the pool cleaner booster air exists coming on when the pump is not running.If you have any questions please contact us through our website at: https://www.poolspecialists.com/The pump either does not start at all, or attempts a start but shuts off after about a minute. The App show system Alerts Pump 1: Communication lost and Chlorinator: Communication lost. Contractor's Assistant: I'm sorry to hear about the issues you're experiencing with your newly installed Pentair Superflow VST and ScreenLogic. Has the pump ...Note: These circuits do not switch the pump on. Page 67: Easytouch Error Messages EasyTouch Error Messages Error Messages If the system detects that a sensor is not connected to the EasyTouch load center or it is defective, an error message is displayed in the "Diagnostics" menu. The following lists the sensor errors. . y l "...The EasyTouch PL4 and PSL4 control systems offer an economical and sophisticated solution for controlling filtration, pumps, lighting, chemical management, and more. Tailored to your needs, the EasyTouch PL4 is designed for a single body of water, while the EasyTouch PSL4 is perfect for controlling both pool and spa combinations.From the manual: The pump control panel is disabled when communicating with an EasyTouch and/or IntelliTouch system. The EasyTouch and/or IntelliTouch system will not start communicating with the pump until the pump is assigned to a circuit. The default pump address is “1” (only address for EasyTouch system).Sep 2, 2023 ... A tutorial on how to Change the Pentair Easy Touch system Pump Speed.Founder codes for Pentair Easy Touch. Thread starter jkusmier; Start scheduled Jun 4, 2009; ... when my IntelliChlor IC40 ended communicating w/ my EasyTouch ... but 20% lives too much. Don't want to reduce pump time, that I'm forced to fixed output to 0%, which deaths target of having spent money for automation. But not …Apr 7, 2019 · Easy Touch 4P (520591) Does anyone know how or if it is possible to connect a Pentair 3HP Intelliflo VSF pump and a 1.5HP Superflo VS to the Easy Touch control unit? Right now I have the 3HP VSF connected with the included 2 conductor com cable to the com terminal in the Easy Touch. That makes perfect sense.I'm using compool Pentair Easy Touch to control the filtering system. However, after opening this year, the 'scheduled' function doesn't work correctly. I set the pump work from 12p to 8p and it conti …Google "pentair easytouch indoor control panel" for images of it. If you press the "pool" button which has a green light next to it to indicate if it's on or off, it will turn off the pool pump. You can also do the same thing from the large outdoor panel by pressing the mode button, which will select through three modes.If you have any questions please contact us through our website at: https://www.poolspecialists.com/Step 2. Use a small tipped object (such as an unfolded paper clip) to move the switches of the receiver. The receiver board has two sections of switches: "S1" and "S2." The "S1" switches control the communication link with the remote. The "S2" switch area controls the automatic countdown cycle for the shutdown of the spa jets.I have a pentair easy touch system and when I turn to Spa mode the pump is not coming on. It works fine in pool mode and the valves turn when spa mode is on but the pump doesn't come on. ... I sporadically get a "pump 1 communication lost" alert on my Pentair app to the Inteliflow VSF pump. The pump works in manual. The relays on the ...Part # EasyTouch Systems without IntelliChlor Transformer Built-in 520591 EasyTouch System 4P Single Body (base system—no indoor control panel, no actuators) 520703 EasyTouch System 8P Single Body (base system—no indoor control panel, no actuators) 520538 EasyTouch System 4 Pool/Spa (base system—no indoor control panel, 2 actuators)New pool owner: I have a Pentair Easytouch control 4 with a Pentair intelliflo VSF pump. Every morning I receive alerts on the Screen logic app indicating the pump has lost communication and there is a power outage. On the Easytouch pannel, the red LED over the F button is out.Are you having trouble with your pump communication? Join the discussion on Trouble Free Pool and get advice from other pool owners.• TIME LED: View the current EasyTouch or IntelliTouch system time. • RPM LED: Press the / button to step increment the pump speed (RPM) for the IntelliFlo® VS Pump(*). • GPM LED: Press the / button to step increment the flow rate (GPM) for the IntelliFlo VF pump*. See page 18 and 19 for IntelliTouch and EasyTouch menu setup information.Gather your supplies: a white cake mix, eggs, oil, pool steps, and clear aqua gel. Make the cake mix according to the package directions. Grease and flour the pool steps. Pour half of the batter into each step. Bake at 350 degrees for 30 minutes or until a toothpick comes out clean when inserted into the center of the cake.For Mac, Download ScreenLogic Connect for Mac Computers (Only compatible with Mac OS versions 10.8 to 10.14. Not compatible with Mac OS 10.15 and higher.) Download the latest version; If your browser shows an information bar, click and then select "Download file" When prompted, click Desktop to save the file on your desktopSuperFlo pumps are a high-performing drop-in replacement for the Hayward® Super Pump.†. Certain models meet updated DOE minimum efficiency requirements. Available only in store from Pentair dealers or retail stores. 4.7. |. 52 Reviews. 43 out of 47 (91%) reviewers recommend this product. 101 questions.EasyTouch PL4 and PSL4 control systems are the economical way to bring sophisticated automation capabilities to standard pools, for control over filtration pumps, lighting, chemical management and more. Like Pentair control systems with broader capabilities, EasyTouch PL4 and PSL4 control systems include an easy to use control panel built into an outdoor …How to turn a Pentair EasyTouch to auto mode. Pentair EasyTouch pool automation is equipped with three modes; auto, service, and time-out. The modes are typically used by our pool technicians in order to perform maintenance tasks on your pool. To help better understand the functionality here is a quick description of each of the modes.Pentair Self Test Fail Code 4 indicates a problem with the pressure switch. This code may be triggered when there is an issue with the pressure switch not detecting water flow or not resetting correctly. To fix this, first check for any blockages in the filter and pump system, then look for any loose wires around the pressure switch.equipment such as a pressure side cleaner booster pump, tthe PL4/ PSL4 Control System monitors the main pump (if it is an IntelliFlo pump). If the pump stops, the control system will delay the cleaner function. This may take as much as 30 seconds. The PL4/PSL4 Control System will hold the cleaner off until the pump is running again.We would like to show you a description here but the site won't allow us.Grab a paper clip and press the reset button three times in the hole of the protocol adapter before waiting 30 seconds for it to work again. Try uninstalling and then reinstalling the app once too. A Different Subnet. A different subnet can block out both connections. In this case, you may not see any of the Screenlogic protocol adapters when ...Using a medium flat blade screwdriver, loosen the two plastic screws on the front cover and open the front cover. Mount the enclosure on a flat surface such as a wall or post. Mark each mounting screw hole location. Drill four 1⁄4 inch (6.35 mm) holes. Install anchors if necessary and one screw for each enclosure hole.Remove the pump pot plug, pump volute plug, the drain plugs next to the heater and the plug found at your dial valve. While most frozen plugs can be removed by hand, if needed, use a pair of pliers for extra leverage. Disconnect your motor. As an extra step of protection, homeowners can disconnect their motor from power, if able.To connect your pentair screenlogic app, follow these simple steps: 1. Download and install the pentair screenlogic app from your device’s app store. 2. Ensure your pentair pool or spa system is connected to your home’s wi-fi network. 3. Open the screenlogic app and tap on “connect” or “enter ip address” if prompted.Home - Trouble Free Pool | Trouble Free PoolDec 27, 2015 · SWG Type. Pentair Intellichlor IC-60. Dec 27, 2015. #2. Reset the EasyTouch panel. See if that corrects the problem. You should also check the antenna wiring (you have to remove the front of the panel to exposed the circuit board) and check that no wires are loose. Sent from my iPhone using Tapatalk,16k gal SWG pool (All Pentair), QuadDE100 ...Home - Trouble Free Pool | Trouble Free Pool• STOP – Take Pictures of inside of Salt Cell – NOT a warranty. MUST get Customer Approval to Clean for $75. Use Muriatic Acid (NOT Sulfuric Acid) – 1part Muriatic Acid to 4 parts Water let set for 15 minutes and rinse. If calcium deposits still present - 1part Muriatic Acid to 1 part Water let set for 15 minutes and rinse.Running a Pentair easy touch controller with an inteliflow 2 vst.both are 4 years old This am the schedule did not turn on the pump and I cannot get the ET controller to turn the pump …If you have any questions please contact us through our website at: https://www.poolspecialists.com/IntelliSync Pool Pump Control & Monitoring System. Prowler 930W Robotic Cleaner. Color Sync™ Controller for Pentair LED Lights. ... Bring your smart home's water to life while staying smart, connected and protected with the Pentair Home app …3. Run Automation. If you live in a climate where you are experiencing freezing temperatures for a short period, you can enable freeze protection on your pool automation system. Having pool automation allows your pool equipment to continue running until normal temperatures return. If you do not have pool automation, run your pool equipment 24/7 ...Mar 3, 2018 · At this point scroll till " pool" comes up in the bottom line of the display. If you dont see "pool" in any of the 8 presets, that could be why you aren't getting the pump going on. Once you connect the comm cable to the E/T and the pump, you need to assign a speed to any aux you want to assign the pump to.Our Pentair pool heater troubleshooting guide will have your heater up and running in no time! ... Service pump and/or filter. Service heat exchanger. Correct water chemistry. Service bypass valve. ... Feel free to leave us a message and we will be in touch as soon as an agent is available. For urgent questions, you can reach us directly at 1 ...This avoids expensive wiring and installation costs to make an EasyTouch system affordable for any budget. Available in Four-Function or Eight-Function Systems. Supports variable speed or variable flow pumps, pool lighting, landscape lighting, waterfalls, fountains, heaters and more. Include 150-amp breaker base with space for 10 1-in. breakers.Our Pentair pool heater troubleshooting guide will have your heater up and running in no time! ... Service pump and/or filter. Service heat exchanger. Correct water chemistry. Service bypass valve. ... Feel free to leave us a message and we will be in touch as soon as an agent is available. For urgent questions, you can reach us directly at 1 ...Fairbanks Nijhuis Pumps Manual Library. Go Back. Customer Service. ... EASYTOUCH SYSTEMS WITHOUT INTELLICHLOR TRANSFORMER BUILT-IN, EasyTouch 4 - Pool/Spa (base system - no ICP, 2 actuators) ... From our residential and commercial water solutions, to industrial water management and everything in between, Pentair is focused on smart, sustainable ...Are you having trouble with your pump communication? Join the discussion on Trouble Free Pool and get advice from other pool owners.The QuickTouch II receiver is connected to the EasyTouch, IntelliTouch and SunTouch system via a four-conductor communication cable. For receiver antenna location, see page 13. To connect the receiver cable to EasyTouch or IntelliTouch load center: 1. 2. Unlatch the load center front door spring latch, and open the front door. 3.Through the convenience of the Pentair Home app, this pool pump controller* lets you adjust your pump, plus get monitoring alerts on select models. Affordable pool automation: a smart investment in easy control and savings. 24/7 pump control and monitoring via the Pentair Home App. Receive maintenance alerts. Easy installation: plugs into a 120 ...Create lasting memories with Design Pool & Spa. Based in Fairport, NY, we're committed to quality and durability, serving the Greater Rochester area and beyond. Don't hesitate to get in touch with us today at 585-223-8650 or through our contact form to learn more about how we can help you bring your vision to life. contact us.In today’s digital age, where communication is often done through text messages and social media posts, receiving a personalized physical card can be a delightful surprise. Creatin...If it has a digital display on it (newer model of variable speed pump) then the display on the motor should tell you to control it from the easytouch panel (indicating that they are communicating). If it does tell you to consult the panel, try manually turning it on as listed above.In today’s digital age, email has become an essential means of communication. Whether you are sending a professional email or a personal one, adding a signature at the end of your ...At this low of a speed it looked like the pump was off. Also check the pumps communication to the panel. Go to settings > intelliflo > pump #1 > status. This will display what the easytouch is getting from the pump. If it says No Comm then you may have a bad com wire. It's rare but I have had the RS-485 communication cable go bad.Jimrahbe said: NP, Use your Pentair remote or the little LCD on the EasyTouch and ensure that your pump has speeds assigned to it. Menu Settings IntelliFlo Pump #1 Make sure the pump type is VS Speeds.. Make sure that Pool has a speed assigned to it. Thanks, Jim R.Page 2 EasyTouch/IntelliTouch Control System Upgrade Kits Installation Guide CUSTOMER SERVICE / TECHNICAL SUPPORT Technical Support Customer Service Sanford, North Carolina (8 A.M. to 8.30 PM ET) 8 AM to 5.30 PM — Eastern and Pacific Times Phone: (919) 566-8000 Phone: (800) 831-7133... Page 3 This guide provides installation and operation ...Go to topic listing. Neither air nor water will calibrate. I have followed the instructions in the manual, and can change the numbers, but no matter what changes are made, the changes aren't saved. I'm not too concerned with the air, but with the water being off, the heater won't turn on.Serial COM Port Expansion Installation Guide 2 Connecting Accessories to the Expansion Board If you have existing accessories (IntelliChlor ® Electronic Chlorine Generator, IntelliFlo® Pump) connected to the IntelliTouch control System Personality Board or EasyTouch Control System Main Board COM port, remove the connector withNOW COMPATIBLE WITH THE PENTAIR HOME APP Des copies numériques de tous les manuels IntelliConnect peuvent être trouvées sur www.pentair.com, ou en scannant le code QR fourni. •• Guide d'installation (P/N 523338) • Guide d'utilisation (P/N 523325) Se pueden encontrar copias digitales de todos los manuales de IntelliConnect en Chill Out This Summer. Taking a cool plunge on a hot day is simple - the power is in the palm o

Hello, I have a Pentair Pentair 011486 WhisperFlo High Performance Energy Efficient Two Speed Full Rated Pump, 1 Horsepower, 230 Volt, 1 Phase in ground pool pump at my rental house. The tenant said d …IntelliPro pump is being used as either a filtration pump or a solar booster pump, RPM will change and resume to the timed program set speed (RPM). This could take up to one (1) minute. • IntelliFlo/IntelliPro pump connected and communicating with SolarTouch controller: The pump is not being controlled by SolarTouch controller at this time.Jan 13, 2019 · Jim's test shows that the EasyTouch comm port is good, so it's possible that the comm port on the wireless link transceiver is dead. I don't know how far your outdoor panel is from your pool, but you can use a length of 4-conductor cable to temporarily connect the screenlogic's protocol adapter directly to the comm port on the outdoor controller to determine if the wireless link is at fault.† EasyTouch 8 and EasyTouch 4 Pool and spa Control System Installation Guide (this manual) Optional Equipment † IntelliChlor® Electronic Chlorine Generator Electrolytic Cell model IC20 (P/N 520554) or IC40 (P/N 520555) † IntelliChem® no-pump (P/N 521357), one-pump (P/N 521356), two-pump (P/N 521355) † IntelliChlor User’s Guide (P/N ...I'm using compool Pentair Easy Touch to control the filtering system. However, after opening this year, the 'scheduled' function doesn't work correctly. I set the pump work from 12p to 8p and it conti …Tap All to. run the schedule for all the days of the week. 11. To create another schedule, tap Add Program. 12. To delete a schedule: Select the schedule to delete from the list, and tap Delete Program. Note: If the Manual Operation Priority feature is enabled during a scheduled run time, the scheduled. run time is reset to 12 hours (default).Do you know how to drain a waterbed without a pump? Find out how to drain a waterbed without a pump in this article from HowStuffWorks. Advertisement A waterbed is a bed whose matt...Do not plug in the AC adapter to a power source within five (5) feet of the pool and spa. Canadian installations require a minimum of (3) meters from pool water. Do not recharge outdoors. Only use Pentair approved AC adapter transformer. The MobileTouch wireless controller is water resistant and can be exposed to temporary splashing or wet hands.the EasyTouch System Load Center. For even greater convenience, add a wired or wireless remote. Beyond basic equipment control, the EasyTouch System lets you program your equipment for optimum e—ciency. Pumps and lights • IntelliFlo® Variable Speed and Variable Flow Pumps • IntelliBrite® 5G Underwater Color-Changing LED Pool and Spa LightsEasyTouch Control System Main Board Connector from the Expansion board Connect IntelliFlo® Pump wires to two-pin terminal connector Figure 1. IntelliTouch® Control System (Original) Load Center Figure 2. EasyTouch and IntelliTouch Control System (New Style) Load Center 1. Remove the two screws from the back of the load center low voltage ...Hi. My pentair heat pump runs but my heater does not. Why? Contractor's Assistant: I understand having issues with your pool equipment can be frustrating. Can you describe the specific model of your Pentair heat pump? Pentair ultratemp heatpump. Contractor's Assistant: When did you first notice the heater not working? 2 days agoWell. I don't think is the app. Because I cannot connect from the Pentair Easy Touch remote either. ... I have a aquacal heatwave heat pump/chiller being remotely controlled by the Pentair Intel a Center ScreenLogic app. For some reason the Pentair screen logic app does not see or is communicating with ...Are you having trouble with your pump communication? Join the discussion on Trouble Free Pool and get advice from other pool owners.Sep 4, 2019 ... Thank you very much! 12:50 · Go to channel · How to PRIME a Swimming Pool Pump | Very Informative! Hallmark Pool Supplies•343K views · 8 videos...I Jane a Pentair Intellitouch system with EasyTouch 8 controller board, solar hot water loop and a VS-3050 pump. They system is about 8 years old. Starting this spring, when the system sees that air temp is sufficient for the solar loop to open, the controller board starts making an erratic using noise, the solar valve opens and closes ...Light It Up. The right lighting can make all the difference when it comes to getting the most enjoyment and relaxation out of your pool. Color Sync™ Controller makes it easy to create and activate lighting scenes for any …7. The system will reset all settings to the factory defaults. Please note that resetting your pentair easy touch will erase all customized settings. It’s important to reconfigure the system according to your preferences after the reset. Conclusion. To sum up, the communication loss of the pentair pump 1 can be a frustrating issue for users.I have a Pentair EasyTouch 8 system. I am appearently not getting power to the main control panel (Display is blank, Remote Control indicates "No Com"). I have checked the circuit breaker in my house panel that feeds the system (Power, no trips) and the system circuit breaker in the Easy Touch load Center (Power, no trips).Pentair EasyTouch 4 Installation Manual (32 pages) Pool and Spa Control System (with optional IntelliChlor Electronic Chlorine Generator) Brand: Pentair | Category: Control Systems | Size: 2.88 MB.Need help with Pentair Easytouch. Thread starter JMTBLee; Start date Jun 8, 2023; Jump to latest Follow Reply Forums. Equipment - Build, Use, and Repair ... if I go out to the variable speed pump, it says "display not active" and there is some pump activity, but just so slow that barely any water is moving. The only way to get the water moving ...Features: Fits Pentair EasyTouch pool and spa automatic control system. 4 circuit system wireless controller replacement kit. Measures 22-1/2-inch length by 5-3/4-inch height by 20-1/2-inch width. Offers scheduling over pool and spa functions. 300′ operational range. Power saving menu option.Mar 1, 2015. #1. We have a 2 1/2 year old SR400NA we use to heat our SPA. Last night the SPA would only heat to 94 degrees as reported by out Pentair Water Easy Touch controller. The water was lukewarm at best. I tried shutting off the breakers to all the pool equipment to see if that woul reset everything, but that did not help.For the fastest service, please submit the warranty information online by clicking on the registration link below. Or, you can mail in your warranty card—just follow the instructions on your product registration warranty card. While the majority of Pentair products are covered by a sixty- (60) day warranty, a select number of products qualify ...FLOW CONTROL. Our variable speed and flow pool pumps adjust to meet your pool's changing needs. *Savings based on variable speed pump compared to a single-speed pump running 12 hours per day at an average of $0.16 per kWH in a 20,000-gallon pool. Actual savings may vary based on local utility rates, pool size, pump run time, pump horsepower ...If the heater did not start disconnect the com wire from the heater firemans switch now and use a jumper or original loop to connect the switch. If heater starts then comm wire is bad. If heater still has not start then remove the ribbon connecting the control membrane from the heater pcb board. Jump the 1&2 pin.(Spa Side Pump#1) pump speed control settings as set in the IntelliFlo menu “PUMP # and TYPE.” 10. Press the Right button to select “Step RPM” Use the Up/ Down button to adjust the step pump speed (10-240) in increments of 10 RPM. 11. Press the Right button to select “Step Size” Use the Up/ Down button to set the step pump speed ...Second Opinion] I have an easy touch pl4/psl4 control system wireless controller that stopped communicating with the pump controls panel. Contractor's Assistant: I'm sorry to hear that your Easy Touch PL4PSL4 control system wireless controller is no longer communicating with the pump controls panel. Have you noticed any other issues with …Mar 2, 2023 · If the heater did not start disconnect the com wire from the heater firemans switch now and use a jumper or original loop to connect the switch. If heater starts then comm wire is bad. If heater still has not start then remove the ribbon connecting the control membrane from the heater pcb board. Jump the 1&2 pin.Low Filter Pressure. Option 1: Check the pump basket and impeller. If the pump basket or impeller is clogged with debris, it can reduce the amount of water that flows through the filter system, resulting in low filter pressure. Simply remove any debris from the pump basket or impeller to increase water flow.Pentair EasyTouch control panel series.Step by step of adding a new pump schedule. What would you like to see next? Let me know in the comments.Please like a...The IntelliChlor SCG is designed only to produce chlorine. The IntelliChlor SCG does not monitor or control chlorine levels in the pool or spa water. It is the pool ownerʼs responsibility for monitoring and maintaining free chlorine levels at the APSP recommended range of 2.0 to 4.0 parts per million (ppm).The Vehicles diesel engine is found in certain years of Vehicles pickups. This engine has an oil pump that helps to move the oil throughout the engine. If this oil pump goes out, t...The best way to isolate whether you have a pump issue or an Easy Touch issue is to isolate the pump and operate it as a stand-alone, where you operate the pump from the pump keypad. If the pump operates properly as a stand-alone pump, the problem is in the controls or the communication cable itself.No, I don't have ScreenLogic, just the Easy Touch remote that is communicating with EasyTouch outdoor panel. The issue here is although the outdoor panel indicates the pump is running on the screen, it's actually not running. If I change to Service mode, then I can manually go to the pump itself and start from there.I have a Pentair Superflo High Performance pump connected to a Pentair Easytouch controller. In Service mode the pump runs 24/7 without fail so overheating is not an issue, but in Automatic mode the p … read more Share. shartson. • 2 yr. ago. I am trying to configure a used Pentair intelliconnect. I think I got

Reviews

Instructions (See page 47 for pump speed setup) When using two-speed pumps manufactured on or...

Read more

PENTAIR AQUATIC SYSTEMS 1620 HAWKINS AVE., SANFORD, NC 27330 • (919) 566-8000 10951 WEST LOS ANGELES AVE., MOORPA...

Read more

Fully automated Pentair system. 3 pumps for edge, floor cleaner, and main pump. All systems wor...

Read more

This avoids expensive wiring and installation costs to make an EasyTouch system affordab...

Read more

16x32 rectangular, 16,500 Gal inground vinyl-lined pool installed 9/2007. Have all Pentair equ...

Read more

After a power outage in my area my Pentair Easy Touch Control System has not worked properly. I am unabl...

Read more

On my pentair vs pump. Power has been checked. No buttons on module react - Answered by a verified Pool and Spa Exp...

Read more